RCX3-SMU FIRMWARE Release Notes

RCX3-SMU Release Notes information.

Updated Version Modification items Impact analysis
[Compatibility]
Impact analysis
[Functional safety]
Dec. 04, 2024 V1.02 1 Improvement of the phenomenon in which a diagnostic error is falsely detected when the PBX connector and dummy connector are swapped The standard value for the TP input discrepancy judgment of the MCU mutual diagnostic function is changed from 24 ms to 800 ms <DF001> MCU mutual diagnostic function
2 Improvement of the phenomenon where a diagnostic error is falsely detected after the speed monitoring function is activated Add “the axis speed must be below the stop speed” as a condition for transitioning from the safe state to the operational state <SF001> STO function
<SF002> SS1-r/t function
3 Fixed a problem where the RCX340 could not be switched to AUTO mode when the parameter data failed When a fault is detected in the parameter data, the parameter values that are applied are the initial values No effect
4 Improvement of the processing time for executing the parameter initialization command Processing time is reduced by omitting some unnecessary processing only when the data is normal <DC019> ROM data diagnosis